Installing an optional mini-PCI-X enablement card Адаптер thinkserver Lenovo Tower Server - TS100 (ThinkServer) - Type 6431

Страница: 59 из 96

background image

Note:

 

The

 

drive

 

cage

 

should

 

be

 

in

 

the

 

open

 

position.

 

This

 

illustration

 

shows

 

it

 

in

 

the

 

closed

 

position.

 

 

8.

   

Press

 

the

 

ServeRAID-MR10i

 

SAS/SATA

 

controller

 

firmly

 

into

 

the

 

connector

 

on

 

the

 

system

 

board.

 

 

9.

   

Take

 

the

 

other

 

end

 

of

 

the

 

signal

 

cable

 

that

 

is

 

attached

 

to

 

the

 

drive

 

backplane

 

section

 

for

 

drive

 

bays

 

0

 

through

 

3

 

(as

 

labeled

 

on

 

the

 

front

 

of

 

the

 

drive

 

cage)

 

and

 

connect

 

it

 

to

 

the

 

connector

 

that

 

is

 

closest

 

to

 

the

 

battery

 

on

 

the

 

ServeRAID-MR10i

 

SAS/SATA

 

controller.

 

If

 

drives

 

are

 

installed

 

in

 

drive

 

bays

 

4

 

through

 

7

 

(as

 

labeled

 

on

 

the

 

front

 

of

 

the

 

drive

 

cage),

 

take

 

the

 

other

 

end

 

of

 

the

 

signal

 

cable

 

that

 

is

 

attached

 

to

 

drive

 

backplane

 

section

 

for

 

drive

 

bays

 

4

 

through

 

7

 

and

 

connect

 

it

 

to

 

the

 

connector

 

that

 

is

 

farthest

 

from

 

the

 

battery

 

on

 

the

 

ServeRAID-MR10i

 

SAS/SATA

 

controller.

 

10.

   

Replace

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly:

 

a.

   

Insert

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly

 

retaining

 

tab

 

over

 

the

 

right

 

edge

 

of

 

the

 

hard

 

disk

 

drive

 

backplane;

 

then,

 

rotate

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly

 

toward

 

the

 

backplane.

 

Do

 

not

 

fully

 

close

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly.

 

b.

   

Route

 

the

 

signal

 

cables

 

and

 

power

 

cable

 

through

 

the

 

slot

 

on

 

the

 

edge

 

of

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly.

 

Make

 

sure

 

that

 

the

 

cables

 

will

 

not

 

be

 

pinched

 

between

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly

 

and

 

the

 

hard

 

disk

 

drive

 

backplane

 

when

 

the

 

assembly

 

is

 

installed.

 

c.

   

Rotate

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly

 

toward

 

the

 

backplane

 

until

 

the

 

release

 

tabs

 

are

 

fully

 

engaged

 

and

 

snap

 

into

 

place.

11.

   

Reconnect

 

the

 

hard

 

disk

 

drive

 

fan

 

assembly

 

cable

 

to

 

the

 

system

 

board.

 

12.

   

Rotate

 

the

 

drive

 

cage

 

back

 

into

 

the

 

server

 

until

 

it

 

stops;

 

then,

 

press

 

and

 

hold

 

the

 

retaining

 

tab

 

on

 

top

 

of

 

the

 

drive

 

cage

 

while

 

you

 

rotate

 

the

 

drive

 

cage

 

into

 

the

 

chassis

 

until

 

it

 

is

 

in

 

the

 

closed

 

position.

 

13.

   

Reinstall

 

the

 

hard

 

disk

 

drives.

Note:

 

Before

 

you

 

continue,

 

check

 

all

 

internal

 

power

 

cables

 

to

 

make

 

sure

 

that

 

they

 

are

 

connected

 

to

 

the

 

system

 

board

 

and

 

other

 

optional

 

devices.

 

14.

   

Install

 

the

 

side

 

cover

 

(see

 

“Reinstalling

 

the

 

side

 

cover”

 

on

 

page

 

52).

 

15.

   

Lock

 

the

 

side

 

cover.

 

16.

   

Reconnect

 

the

 

external

 

cables

 

and

 

power

 

cords;

 

then,

 

turn

 

on

 

the

 

attached

 

devices

 

and

 

turn

 

on

 

the

 

server.

Installing

 

an

 

optional

 

mini-PCI-X

 

enablement

 

card

 

To

 

install

 

an

 

optional

 

mini-PCI-X

 

enablement

 

card,

 

complete

 

the

 

following

 

steps:

 

1.

   

Read

 

the

 

safety

 

information

 

that

 

begins

 

on

 

page

 

v

 

and

 

“Installation

 

guidelines”

 

on

 

page

 

19.

 

2.

   

Turn

 

off

 

the

 

server

 

and

 

all

 

attached

 

devices;

 

then,

 

disconnect

 

all

 

power

 

cords

 

and

 

external

 

cables.

 

3.

   

Unlock

 

and

 

remove

 

the

 

side

 

cover

 

(see

 

“Removing

 

the

 

side

 

cover”

 

on

 

page

 

23).

 

4.

   

Touch

 

the

 

static-protective

 

package

 

that

 

contains

 

the

 

mini-PCI-X

 

enablement

 

card

 

to

 

any

 

unpainted

 

surface

 

on

 

the

 

outside

 

of

 

the

 

server;

 

then,

 

remove

 

mini-PCI-X

 

enablement

 

card

 

from

 

the

 

package.

 

 

Chapter

 

2.

 

Installing

 

optional

 

devices

 

45