LED

 

Description

 

Action

 

RAID

 

A

 

RAID

 

controller

 

error

 

has

 

occurred.

 

1.

   

Make

 

sure

 

that

 

a

 

RAID

 

controller

 

is

 

installed.

 

Note:

 

The

 

server

 

will

 

not

 

start

 

without

 

a

 

RAID

 

controller

 

installed.

 

2.

   

Check

 

the

 

system-error

 

log

 

for

 

information

 

about

 

the

 

error.

 

FAN

 

A

 

fan

 

has

 

failed,

 

is

 

operating

 

too

 

slowly,

 

or

 

has

 

been

 

removed.

 

The

 

TEMP

 

LED

 

might

 

also

 

be

 

lit.

 

Replace

 

the

 

failing

 

fan,

 

which

 

is

 

indicated

 

by

 

a

 

lit

 

LED

 

on

 

the

 

fan

 

itself.

 

TEMP

 

The

 

system

 

temperature

 

has

 

exceeded

 

a

 

threshold

 

level.

 

A

 

failing

 

fan

 

can

 

cause

 

the

 

TEMP

 

LED

 

to

 

be

 

lit.

 

1.

   

Determine

 

whether

 

a

 

fan

 

has

 

failed.

 

If

 

it

 

has,

 

replace

 

it.

 

2.

   

Make

 

sure

 

that

 

the

 

room

 

temperature

 

is

 

not

 

too

 

high.

 

See

 

“Features

 

and

 

specifications”

 

on

 

page

 

3

 

for

 

temperature

 

information.

 

3.

   

Make

 

sure

 

that

 

the

 

air

 

vents

 

are

 

not

 

blocked.

 

4.

   

Call

 

for

 

service.

 

BRD

 

An

 

error

 

has

 

occurred

 

on

 

the

 

system

 

board.

 

1.

   

Check

 

the

 

LEDs

 

on

 

the

 

system

 

board

 

to

 

identify

 

the

 

component

 

that

 

is

 

causing

 

the

 

error.

 

2.

   

Check

 

the

 

system-error

 

log

 

for

 

information

 

about

 

the

 

error.

 

PCI

 

An

 

error

 

has

 

occurred

 

on

 

a

 

PCI

 

bus

 

or

 

on

 

the

 

system

 

board.

 

An

 

additional

 

LED

 

will

 

be

 

lit

 

next

 

to

 

a

 

failing

 

PCI

 

slot.

 

1.

   

Check

 

the

 

LEDs

 

on

 

the

 

PCI

 

slots

 

to

 

identify

 

the

 

component

 

that

 

is

 

causing

 

the

 

error.

 

2.

   

Check

 

the

 

system-error

 

log

 

for

 

information

 

about

 

the

 

error.

 

3.

   

If

 

you

 

cannot

 

isolate

 

the

 

failing

 

adapter

 

through

 

the

 

LEDs

 

and

 

the

 

information

 

in

 

the

 

system-error

 

log,

 

remove

 

one

 

adapter

 

at

 

a

 

time

 

from

 

the

 

failing

 

PCI

 

bus,

 

and

 

restart

 

the

 

server

 

after

 

each

 

adapter

 

is

 

removed.

 

4.

   

Call

 

for

 

service.

  

For

 

more

 

information

 

about

 

diagnostics,

 

see

 

the

 

Hardware

 

Maintenance

 

Manual

 

on

 

the

 

ThinkServer

 

Documentation

 

DVD.

 

 

28

 

ThinkServer

 

RD120

 

Types

 

6444,

 

6445,

 

6446,

 

and

 

6447:

 

User

 

Guide